In an effort to reduce their labor and material expenses, many builders take shortcuts in their forming. Placing wire lathe within a raised wall prevents the proper encapsulation of the reinforcing steel. It also creates a vertical sheer plane throughout the entire wall that promotes weakness, cracking, water infiltration and corrosion.

Tying the lathe onto the steel only allows the shotcrete to encapsulate one side of the rebar. The two planes of concrete are separated by the lathe, as the aggreate cannot pass through the small perforations. Any wall over 8-inches thick requires a double layer of steel.

When doing a raised double curtain of steel, the proper steel overlaps must be maintained on top. Notice how the top bars form an inverted an L? To achieve the proper overlap, they must be bent into an inverted J or U, called stirrups.

Remember, the rule of thumb is an overlap of 40x the bar diameter (e.g. #4 bar/0.5″ would require a 20″ overlap). Take the time to construct forms that are properly blocked off of the steel.

Building quality is not expensive, but it does require that you slow down and pay attention to the details.

Swimming Pool Expert Witness

5/5 - (1 vote)

Paolo Benedetti is the President of Aquatic Technology and better known on social media as the "Swimming Pool Expert Witness". Paolo is an instructor at Watershape University and has authored a myriad of articles on the finer points of pool construction and design. He is a pioneer in the field of aquatic design, constantly pushing the envelope, creating a number of firsts that spawned new trends in the industry.

Continue Reading
Click to comment


Subscribe
Notify of
0 Comments
Inline Feedbacks
View all comments

Op Editorials

Hair Entanglement in Pools, Are Current Standards Adequate?

Published

on

Hair Entanglement in Pools, Are Current Standards Adequate?

When discussing hair entanglement in the pool and how to prevent these types of incidents from occurring, we have to look at a few things. The first is line velocity. If it is low enough, hair won’t be ingested by the pipe and tangled under the drain lid. Suction entrapment wouldn’t occur either, even if a grate were missing.

Video captured a teen girl nearly drowning after getting her hair caught in the pool.

The second issue pertains to the current codes and standards. Some states have state building codes that dictate maximum line velocities for energy efficiency. California and Florida both mandate line velocities of 6 FPS suction and 8 FPS returns for energy efficiency. 

Current Standards

Residential In-ground Pools NSPI-5/2003 (9.2) the line velocities were limited to 8 FPS suction and 10 FPS returns. (9.2.1) the limit through the drain cover was limited to 1.5 FPS.

Residential In-ground Pools NSPI-5/2013 (9.2) the line velocities were limited to 8 FPS suction and 8 FPS returns. (9.2.1) the limit through the drain cover was deferred to the APSP-7 standard.

Suction Entrapment Avoidance APSP-7 (2013) Piping line velocity is not specified, though the flow rate through the drain cover is limited to 1.5 FPS.

APSP-15 Energy Efficiency Code (2011) 6 FPS suction and 8 FPS return

ISPSC 2015 (311.3) limits the line velocities in the return piping to 8 FPS.  (310) It defers to the specifications in APSP-7 (there is no longer a suction line velocity in the standard).

Suction Outlet Fitting Assemblies APSP-16/2017 (3.9.2) piping line velocities were eliminated, though 1.5 FPS remained as the line velocity through the RDP/SOFA.

RE: Hair Entanglement In The Pool - Decreased distance between the suction pipe and the underside of the drain cover increases the flow through the drain cover.
Decreased distance between the suction pipe and the underside of the drain cover increases the flow through the drain cover.

The safety standards are not addressing energy efficiency. Most experts agree that the optimum efficiencies are achieved at 6 FPS suction and 8 FPS return line velocities. The majority of hydraulic engineers are designing at 4.5 FPS suction and 6 FPS return line velocities. This allows for a margin of error and minor deviations that may occur during construction, while still staying below the maximums. Most codes for public pools recognize the need for low line velocities and therefore limit the velocities at the pipe connected to the main drain to 1.5 – 3 FPS.

The safety standards assume two things occur. The first assumption is that the drain sump size is compliant with the SOFA requirements and the manufacturer’s specifications.  Field-built sumps (divots carved out of the shotcrete) are oftentimes too shallow. Few builders thicken the shotcrete around the suction pipes to allow for a proper depth sump.

The decreased distance between the suction pipe and the underside of the drain cover increases the flow through the drain cover. This increases the danger of hair entanglement, as the design standards and flow rate through the cover have been exceeded. Therefore the sumps are of insufficient size and volume to slow the velocity of the water.

Swimming Pool Expert Witness

Photo Credit: Getty Images

5/5 - (1 vote)
Continue Reading

Swimming Pool Expert Witness - Paolo Benedetti

Utilizing Drainage Mats In Pool Construction

Published

on

Pool Contractor Using Drainage Mat During Pool Construction

Retaining walls, raised pool bond beams and pools with adjacent upslopes all require drainage behind them. But it is impossible to install drainage rock up the walls of a shotcrete pool, without extensive over-excavation, forming and backfilling.

Instead of ignoring these conditions, wise contractors utilize drainage mats installed upon the earth, prior to the placement of the shotcrete. This allows the subterranean water to drain vertically into the drain rock under the pool, where it can be collected and discharged (drained to daylight or via a sump pump).

For high-end projects or all tile vessels, this is critical in reducing negative side water infiltration from the soils. Water passes through the geofabric and into the air gap created by the dimples in the plastic sheet. The drainage mats are available with dimples of various sizes to match the anticipated water flow.

Drainage mats can also be used horizontally between coffers and vessels to assist in the lateral discharge of water. The drainage mats can be nailed to the soil prior to steel placement or utilized in place of steel-tex.

Photo Credits: Carlisle Coatings & Waterproofing Systems

Swimming Pool Expert Witness

5/5 - (1 vote)
Continue Reading

Swimming Pool Expert Witness - Paolo Benedetti

Indoor Pools & Water Vapor, What You Need To Know

Published

on

Indoor Pools & Water Vapor, What You Need To Know

Indoor pools are very unique. The water vapor escaping from the pool is trapped in the building envelope. These vapors are potentially corrosive, as they contain chlorine, chloramines, or ozone. The water can have destructive consequences and pose serious health issues if the building is constructed incorrectly.

Dehumidification of indoor pools is absolutely essential in order to avoid costly damage and repair work.
Dehumidification of indoor pools is absolutely essential in order to avoid costly damage and repair work.

Dehumidification for Indoor Pools

There is no such thing as an oversized dehumidification system. But the lack of a dehumidifier (or an undersized one) allows the water vapor to accumulate and penetrate the building envelope. Water vapor inside the walls can cause corrosion of the structural beams, braces, and brackets, corrosion of the wiring and electrical components, foster mold and algae growth, rusting of HVAC ducts, or promote dry rot of wooden elements. Excess water vapor in the building can lead to a series of air-borne health maladies or bacterial infections.

Indoor pool mold from excess water vapor.
Indoor pool mold from excess water vapor.

Been There, Done That

Cheap clients who do not want to pay for the installation or operation of a dehumidification system, think that they can reinvent the wheel with exhaust fans, sliding doors, skylights, ceiling fans, or other schemes. Trust us, they have been tried countless times without success.

Proper Building Envelope for Indoor Pools

It is important to install a vapor barrier and use moisture-resistant construction materials to prevent the migration of moisture into the walls and ceiling. Electrical outlets, fixtures, and penetrations must be sealed against vapor intrusion.

Without Vapor Barrier vs With Vapor Barrier - Indoor Pools
Indoor Pools – Without Vapor Barrier VS With Vapor Barrier – Photo Credit: Aquatic Mechanical Design

Air Pressure in Indoor Pools

The air pressure within the swimming pool enclosure must be less than the adjacent spaces. Maintaining a high pressure in the adjacent spaces ensures that the water vapor does not migrate.

Operational Cost

Operating a dehumidification and air handling system to control the air pressures, temperatures and humidity are expensive to operate. Failure to operate these systems properly will result in vapor migration and degradation of the building. Maintaining the proper temperatures is also important in controlling the creation of water vapor (evaporation).

Automatic Pool Cover

Using a pool cover does not eliminate the need for a dehumidification system. It will help reduce the vapors, but it will not eliminate them. The installation of a cover allows for the reduction in the size of the dehumidification system, as the loads are reduced.

Qualified Indoor Air Quality Expert

We do not profess to be experts in this field. Though we have built a number of indoor pools, we rely upon specialists in this field. Most mechanical engineers or dehumidifier manufacturers do not possess the skills to properly design the HVAC/Dehumidification system, vapor barriers, building envelope, ducting sizes, or air handling register/return locations.

Non-Corrosive Air Ducts

Properly constructed indoor pool air handling systems utilize non-corrosive plastic ducting, registers, and returns. Galvanized sheet metal ducting quickly begins to corrode in an indoor pool environment. Indoor pools can be a source for year-round enjoyment of a pool. But they require a properly designed and built enclosure, in order to protect the rest of the building and occupants’ health.

Swimming Pool Expert Witness

5/5 - (12 votes)
Continue Reading
Follow us on Google News
Sponsored Advertisement
Sponsored Advertisement
Sponsored Advertisement
CPO School - Space Coast Pool SchoolSponsored Advertisement

Pool Service Software

Pool Service SoftwareSponsored Advertisement
Virginia Commercial Pool BuildersSponsored Advertisement
Houston Pool Builders - Beyond Blue PoolsSponsored Advertisement
Sponsored Advertisement
New Orleans Pool Builders - Baton Rouge Pool BuildersSponsored Advertisement

Pool Monitoring Device

Pool Monitoring DeviceSponsored Advertisement
Pool Magazine App on Google PlayPool Magazine App on Apple Store

Download the NEW Pool Magazine App

Recent Pool News

Advertisement
Become a Member of the Pool & Hot Tub Alliance

Pool Monitoring Device

Pool Monitoring Device
We Build Professionals - Genesis - The World Has Changed, And So Have We.

Pool News

Subscribe to Pool Magazine. Join our mailing list.
Subscribe to Pool Magazine on Google News and Join our Mailing list to receive pool news right in your inbox!
Subscribe to Pool Magazine
Pool News & Features
* indicates required
* indicates required
Subscribe to Pool Magazine
0
Would love your thoughts, please comment.x
()
x